| Modell | EHS Standard in CFG | EHS Standard in FG | EHS CFG Flex | EHS High Precision in CFG | EHS High Precision in FG | EHS Lower Current | EHS Stack |
|---|---|---|---|---|---|---|---|
| Kanäle | 4 - 16 | 4 - 16 | 16 - 48 | 4 - 16 | 4 - 16 | 4 - 16 | 8 - 16 |
| Vnom | 100V - 20kV | 100V - 20kV | 100V - 3kV | 100V - 20kV | 100V - 20kV | 100V - 20kV | 400V - 800V |
| Vin | 24V, 5V | 24V, 5V | 24V, 5V | 24V, 5V | 24V, 5V | 24V, 5V | 24V, 5V |
| Ripple & Noise | 3mV - 10mV | 3mV - 10mV | 5 - 10 | 3mV - 10mV | 3mV - 10mV | 3mV - 10mV | - |
| HV-Konnektor | SHV, KINGS, REDEL | SHV, KINGS, REDEL | SHV, REDEL | KINGS, SHV, BNC, REDEL | SHV, KINGS, BNC, REDEL | BNC, SHV, KINGS, REDEL | REDEL |
| Steuerung | iCS | iCS | iCS | iCS | iCS | iCS | iCS |
| Optionen | ID IU SLA SLP | ID IU SLA SLP F02 F20 | SLA SLP | 1CR ID IU L TC SLA SLP | L | ID IU L TC | ID IU NID NIU SLA SLP |
| Handbuch | Handbuch EHS | Handbuch EHS | Handbuch EHS | Handbuch EHS | Handbuch EHS | Handbuch EHS | Handbuch EHS Stack |
| Datenblatt | siehe Konfigurationen | siehe Konfigurationen | siehe Konfigurationen | siehe Konfigurationen | siehe Konfigurationen | siehe Konfigurationen | siehe Konfigurationen |
| Abb. | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
EHS
Hochpräzises HV-Modul in verschiedenen Floating Versionen
- Komplettes Sortiment an Vielkanal- modulen von 100 V bis 10 kV (typ. 9 W pro Kanal)
- Geringe Restwelligkeit
- Spannungs- oder Stromregelung pro Kanal
- Hardware Strom- und Spannungslimit pro Modul
- Programmierbare Trip-Parameter
- 24 bit ADC, 16-20 bit DAC
- Schutzeinrichtungen, Sicherheitsstromschleife, optional INHIBIT pro Kanal
aktuell
neu
geplant
abgekündigt
Gruppe | Modell | Vnom | Inom | Pnom/ch | Kanäle | Polarität | Ripple & Noise | Schnittst. | HV-Konnektor | Gehäuse | Optionen | Abb. | Handbuch |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| EHS Standard in CFG | EHS F001x Art.-Nr.: EH160001x106 konfigurieren | 100V | 10mA | 1W | 16 | custom | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS F001n Art.-Nr.: EH160001n106 konfigurieren | 100V | 10mA | 1W | 16 | negativ | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS F001p Art.-Nr.: EH160001p106 konfigurieren | 100V | 10mA | 1W | 16 | positiv | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS F005n Art.-Nr.: EH160005n156 konfigurieren | 500V | 15mA | 8W | 16 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS F005p Art.-Nr.: EH160005p156 konfigurieren | 500V | 15mA | 8W | 16 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS F010n Art.-Nr.: EH160010n805 konfigurieren | 1kV | 8mA | 8W | 16 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS F010p Art.-Nr.: EH160010p805 konfigurieren | 1kV | 8mA | 8W | 16 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS F020x Art.-Nr.: EH160020x405 konfigurieren | 2kV | 4mA | 8W | 16 | custom | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS F020n Art.-Nr.: EH160020n405 konfigurieren | 2kV | 4mA | 8W | 16 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS F020p Art.-Nr.: EH160020p405 konfigurieren | 2kV | 4mA | 8W | 16 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS F030n Art.-Nr.: EH160030n305 konfigurieren | 3kV | 3mA | 8W | 16 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS F030p Art.-Nr.: EH160030p305 konfigurieren | 3kV | 3mA | 8W | 16 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS F040n Art.-Nr.: EH160040n205 konfigurieren | 4kV | 2mA | 8W | 16 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS F040p Art.-Nr.: EH160040p205 konfigurieren | 4kV | 2mA | 8W | 16 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS F060n Art.-Nr.: EH160060n105 konfigurieren | 6kV | 1mA | 6W | 16 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS F060p Art.-Nr.: EH160060p105 konfigurieren | 6kV | 1mA | 6W | 16 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8001x Art.-Nr.: EH080001x106 konfigurieren | 100V | 10mA | 1W | 8 | custom | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8001n Art.-Nr.: EH080001n106 konfigurieren | 100V | 10mA | 1W | 8 | negativ | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8001p Art.-Nr.: EH080001p106 konfigurieren | 100V | 10mA | 1W | 8 | positiv | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8005n Art.-Nr.: EH080005n156 konfigurieren | 500V | 15mA | 8W | 8 | negativ | 10mV | CAN | REDEL | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8005p Art.-Nr.: EH080005p156 konfigurieren | 500V | 15mA | 8W | 8 | positiv | 10mV | CAN | REDEL | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8010x Art.-Nr.: konfigurieren | 1kV | 8mA | 8W | 8 | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS | |
| EHS Standard in CFG | EHS 8010x Art.-Nr.: EH080010x805 konfigurieren | 1kV | 8mA | 8W | 8 | custom | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8010n Art.-Nr.: EH080010n805 konfigurieren | 1kV | 8mA | 8W | 8 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8010p Art.-Nr.: EH080010p805 konfigurieren | 1kV | 8mA | 8W | 8 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8020x Art.-Nr.: EH080020x405 konfigurieren | 2kV | 4mA | 8W | 8 | custom | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8020n Art.-Nr.: EH080020n405 konfigurieren | 2kV | 4mA | 8W | 8 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8020p Art.-Nr.: EH080020p405 konfigurieren | 2kV | 4mA | 8W | 8 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8030x Art.-Nr.: EH080030x305 konfigurieren | 3kV | 3mA | 8W | 8 | custom | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8030n Art.-Nr.: EH080030n305 konfigurieren | 3kV | 3mA | 8W | 8 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8030p Art.-Nr.: EH080030p305 konfigurieren | 3kV | 3mA | 8W | 8 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8040n Art.-Nr.: EH080040n205 konfigurieren | 4kV | 2mA | 8W | 8 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8040p Art.-Nr.: EH080040p205 konfigurieren | 4kV | 2mA | 8W | 8 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8060x Art.-Nr.: EH080060x105 konfigurieren | 6kV | 1mA | 6W | 8 | custom | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8060n Art.-Nr.: EH080060n105 konfigurieren | 6kV | 1mA | 6W | 8 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 8060p Art.-Nr.: EH080060p105 konfigurieren | 6kV | 1mA | 6W | 8 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 40100n Art.-Nr.: EH040100n754 konfigurieren | 10kV | 0.75mA | 7W | 4 | negativ | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 40100x Art.-Nr.: EH040100p754 konfigurieren | 10kV | 0.75mA | 7W | 4 | positiv | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 40100x Art.-Nr.: EH040100x754 konfigurieren | 10kV | 0.75mA | 7W | 4 | custom | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 40200n Art.-Nr.: EH040200n404 konfigurieren | 20kV | 0.4mA | 8W | 4 | negativ | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 40200p Art.-Nr.: EH040200p404 konfigurieren | 20kV | 0.4mA | 8W | 4 | positiv | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 40200x Art.-Nr.: EH040200x404 konfigurieren | 20kV | 0.4mA | 8W | 4 | custom | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 4080n Art.-Nr.: EH040080n105 konfigurieren | 8kV | 1mA | 8W | 4 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 4080p Art.-Nr.: EH040080p105 konfigurieren | 8kV | 1mA | 8W | 4 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 4080x Art.-Nr.: EH040080x105 konfigurieren | 8kV | 1mA | 8W | 4 | custom | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 40150n Art.-Nr.: EH040150n504 konfigurieren | 15kV | 0.5mA | 8W | 4 | negativ | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 40150p Art.-Nr.: EH040150p504 konfigurieren | 15kV | 0.5mA | 8W | 4 | positiv | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in CFG | EHS 40150x Art.-Nr.: EH040150x504 konfigurieren | 15kV | 0.5mA | 8W | 4 | custom | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS F601x Art.-Nr.: EH166001x156 konfigurieren | 100V | 10mA | 1W | 16 | custom | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS F601n Art.-Nr.: EH166001n156 konfigurieren | 100V | 10mA | 1W | 16 | negativ | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS F601p Art.-Nr.: EH166001p156 konfigurieren | 100V | 10mA | 1W | 16 | positiv | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS F605n Art.-Nr.: EH166005n156 konfigurieren | 500V | 15mA | 7.5W | 16 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS F605p Art.-Nr.: EH166005p156 konfigurieren | 500V | 15mA | 7.5W | 16 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS F610n Art.-Nr.: EH166010n805 konfigurieren | 1kV | 8mA | 8W | 16 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS F610p Art.-Nr.: EH166010p805 konfigurieren | 1kV | 8mA | 8W | 16 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS F620n Art.-Nr.: EH166020n405 konfigurieren | 2kV | 4mA | 8W | 16 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS F6 20n Art.-Nr.: EH166020n105 konfigurieren | 2kV | 1mA | 2W | 16 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS F620p Art.-Nr.: EH166020p405 konfigurieren | 2kV | 4mA | 8W | 16 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS F630n Art.-Nr.: EH166030n305 konfigurieren | 3kV | 3mA | 9W | 16 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS F630p Art.-Nr.: EH166030p305 konfigurieren | 3kV | 3mA | 9W | 16 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS F640n Art.-Nr.: EH166040n205 konfigurieren | 4kV | 2mA | 8W | 16 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS F640p Art.-Nr.: EH166040p205 konfigurieren | 4kV | 2mA | 8W | 16 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS F660n Art.-Nr.: EH166060n105 konfigurieren | 6kV | 1mA | 6W | 16 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS F660p Art.-Nr.: EH166060p105 konfigurieren | 6kV | 1mA | 6W | 16 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 8601x Art.-Nr.: EH086001x106 konfigurieren | 100V | 10mA | 1W | 8 | custom | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 8601n Art.-Nr.: EH086001n106 konfigurieren | 100V | 10mA | 1W | 8 | negativ | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 8601p Art.-Nr.: EH086001p106 konfigurieren | 100V | 10mA | 1W | 8 | positiv | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 8605n Art.-Nr.: EH086005n156 konfigurieren | 500V | 15mA | 7.5W | 8 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 8605p Art.-Nr.: EH086005p156 konfigurieren | 500V | 15mA | 7.5W | 8 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 8610n Art.-Nr.: EH086010n805 konfigurieren | 1kV | 8mA | 8W | 8 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 8610p Art.-Nr.: EH086010p805 konfigurieren | 1kV | 8mA | 8W | 8 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 8620n Art.-Nr.: EH086020n405 konfigurieren | 2kV | 4mA | 8W | 8 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 8620p Art.-Nr.: EH086020p405 konfigurieren | 2kV | 4mA | 8W | 8 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 8630n Art.-Nr.: EH086030n305 konfigurieren | 3kV | 3mA | 9W | 8 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 8630p Art.-Nr.: EH086030p305 konfigurieren | 3kV | 3mA | 9W | 8 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 8640n Art.-Nr.: EH086040n205 konfigurieren | 4kV | 2mA | 8W | 8 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 8640p Art.-Nr.: EH086040p205 konfigurieren | 4kV | 2mA | 8W | 8 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 8660n Art.-Nr.: EH086060n105 konfigurieren | 6kV | 1mA | 6W | 8 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 8660p Art.-Nr.: EH086060p105 konfigurieren | 6kV | 1mA | 6W | 8 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 46200n Art.-Nr.: EH046200n404 konfigurieren | 20kV | 0.4mA | 8W | 4 | negativ | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 46200p Art.-Nr.: EH046200p404 konfigurieren | 20kV | 0.4mA | 8W | 4 | positiv | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 46200x Art.-Nr.: EH046200x404 konfigurieren | 20kV | 0.4mA | 8W | 4 | custom | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 4680n Art.-Nr.: EH046080n105 konfigurieren | 8kV | 1mA | 8W | 4 | negativ | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 4680p Art.-Nr.: EH046080p105 konfigurieren | 8kV | 1mA | 8W | 4 | positiv | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 4680x Art.-Nr.: EH046080x105 konfigurieren | 8kV | 1mA | 8W | 4 | custom | 10mV | CAN | SHV | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 46100x Art.-Nr.: EH046100x754 konfigurieren | 10kV | 0.75mA | 5W | 4 | custom | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 46100n Art.-Nr.: EH046100n754 konfigurieren | 10kV | 0.75mA | 5W | 4 | negativ | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 46100p Art.-Nr.: EH046100p754 konfigurieren | 10kV | 0.75mA | 5W | 4 | positiv | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 46150n Art.-Nr.: EH046150n504 konfigurieren | 15kV | 0.5mA | 7.5W | 4 | negativ | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 46150p Art.-Nr.: EH046150p504 konfigurieren | 15kV | 0.5mA | 7.5W | 4 | positiv | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Standard in FG | EHS 46150x Art.-Nr.: EH046150x504 konfigurieren | 15kV | 0.5mA | 7.5W | 4 | custom | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS CFG Flex | EHS 305 30n Art.-Nr.: EH485030n105 konfigurieren | 3kV | 1mA | 48 | negativ | 10 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 185 20p Art.-Nr.: EH245020p155 konfigurieren | 2kV | 1.5mA | 24 | positiv | 10 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 185 20n Art.-Nr.: EH245020n155 konfigurieren | 2kV | 1.5mA | 24 | negativ | 10 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 305 20p Art.-Nr.: EH485020p155 konfigurieren | 2kV | 1.5mA | 48 | positiv | 10 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 305 20n Art.-Nr.: EH485020n155 konfigurieren | 2kV | 1.5mA | 48 | negativ | 10 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS F5 30p Art.-Nr.: EH165030p105 konfigurieren | 3kV | 1mA | 16 | positiv | 10 | CAN | SHV | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS F5 30n Art.-Nr.: EH165030n105 konfigurieren | 3kV | 1mA | 16 | negativ | 10 | CAN | SHV | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS F18 30p Art.-Nr.: EH245030p105 konfigurieren | 3kV | 1mA | 24 | positiv | 10 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS F18 30n Art.-Nr.: EH245030n105 konfigurieren | 3kV | 1mA | 24 | negativ | 10 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 305 30p Art.-Nr.: EH485030p105 konfigurieren | 3kV | 1mA | 48 | positiv | 10 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS F5 20n Art.-Nr.: EH165020n155 konfigurieren | 2kV | 1.5mA | 16 | negativ | 10 | CAN | SHV | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS F5 10x Art.-Nr.: EH165010x305 konfigurieren | 1kV | 3mA | 16 | custom | 10 | CAN | SHV | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 305 20X Art.-Nr.: EH485020X155 konfigurieren | 2kV | 1.5mA | 48 | custom | 10 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 305 05p Art.-Nr.: EH485005p605 konfigurieren | 500V | 6mA | 48 | positiv | 10 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS F5 01n Art.-Nr.: EH165001n106 konfigurieren | 100V | 10mA | 16 | negativ | 5 | CAN | SHV | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 185 01p Art.-Nr.: EH245001p106 konfigurieren | 100V | 10mA | 24 | positiv | 5 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 185 01n Art.-Nr.: EH245001n106 konfigurieren | 100V | 10mA | 24 | negativ | 5 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 305 01p Art.-Nr.: EH485001p106 konfigurieren | 100V | 10mA | 48 | positiv | 5 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 305 01n Art.-Nr.: EH485001n106 konfigurieren | 100V | 10mA | 48 | negativ | 5 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS F5 05p Art.-Nr.: EH165005p605 konfigurieren | 500V | 6mA | 16 | positiv | 10 | CAN | SHV | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS F5 05n Art.-Nr.: EH165005n605 konfigurieren | 500V | 6mA | 16 | negativ | 10 | CAN | SHV | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 185 05p Art.-Nr.: EH245005p605 konfigurieren | 500V | 6mA | 24 | positiv | 10 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 185 05n Art.-Nr.: EH245005n605 konfigurieren | 500V | 6mA | 24 | negativ | 10 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS F5 01p Art.-Nr.: EH165001p106 konfigurieren | 100V | 10mA | 16 | positiv | 5 | CAN | SHV | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 305 05n Art.-Nr.: EH485005n605 konfigurieren | 500V | 6mA | 48 | negativ | 10 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS F5 10p Art.-Nr.: EH165010p305 konfigurieren | 1kV | 3mA | 16 | positiv | 10 | CAN | SHV | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS F5 10n Art.-Nr.: EH165010n305 konfigurieren | 1kV | 3mA | 16 | negativ | 10 | CAN | SHV | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 185 10p Art.-Nr.: EH245010p305 konfigurieren | 1kV | 3mA | 24 | positiv | 10 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 185 10n Art.-Nr.: EH245010n305 konfigurieren | 1kV | 3mA | 24 | negativ | 10 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 305 10p Art.-Nr.: EH485010p305 konfigurieren | 1kV | 3mA | 48 | positiv | 10 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS 305 10n Art.-Nr.: EH485010n305 konfigurieren | 1kV | 3mA | 48 | negativ | 10 | CAN | REDEL | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS CFG Flex | EHS F5 20p Art.-Nr.: EH165020p155 konfigurieren | 2kV | 1.5mA | 16 | positiv | 10 | CAN | SHV | 19" Einschub Kassette | SLA SLP | ![]() | Handbuch EHS | |
| EHS High Precision in CFG | EHS 8201n Art.-Nr.: EH082001n106 konfigurieren | 100V | 10mA | 1W | 8 | negativ | 3mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 8201p Art.-Nr.: EH082001p106 konfigurieren | 100V | 10mA | 1W | 8 | positiv | 3mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 8205n Art.-Nr.: EH082005n106 konfigurieren | 500V | 10mA | 5W | 8 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 8205p Art.-Nr.: EH082005p106 konfigurieren | 500V | 10mA | 5W | 8 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 8210n Art.-Nr.: EH082010n805 konfigurieren | 1kV | 8mA | 8W | 8 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 8210p Art.-Nr.: EH082010p805 konfigurieren | 1kV | 8mA | 8W | 8 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 8220n Art.-Nr.: EH082020n405 konfigurieren | 2kV | 4mA | 8W | 8 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 8220p Art.-Nr.: EH082020p405 konfigurieren | 2kV | 4mA | 8W | 8 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 8230n Art.-Nr.: EH082030n305 konfigurieren | 3kV | 3mA | 9W | 8 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 8230p Art.-Nr.: EH082030p305 konfigurieren | 3kV | 3mA | 9W | 8 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 8240n Art.-Nr.: EH082040n205 konfigurieren | 4kV | 2mA | 8W | 8 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 8240p Art.-Nr.: EH082040p205 konfigurieren | 4kV | 2mA | 8W | 8 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 8260n Art.-Nr.: EH082060n105 konfigurieren | 6kV | 1mA | 6W | 8 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 8260p Art.-Nr.: EH082060p105 konfigurieren | 6kV | 1mA | 6W | 8 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS F201n Art.-Nr.: EH162001n106 konfigurieren | 100V | 10mA | 1W | 16 | negativ | 3mV | CAN | BNC | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS F201p Art.-Nr.: EH162001p106 konfigurieren | 100V | 10mA | 1W | 16 | positiv | 3mV | CAN | BNC | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS F205n Art.-Nr.: EH162005n106 konfigurieren | 500V | 10mA | 5W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS F205p Art.-Nr.: EH162005p106 konfigurieren | 500V | 10mA | 5W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS F210n Art.-Nr.: EH162010n805 konfigurieren | 1kV | 8mA | 8W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS F210p Art.-Nr.: EH162010p805 konfigurieren | 1kV | 8mA | 8W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS F220n Art.-Nr.: EH162020p405 konfigurieren | 2kV | 4mA | 8W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS F220n Art.-Nr.: EH162020n405 konfigurieren | 2kV | 4mA | 8W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS F230n Art.-Nr.: EH162030n305 konfigurieren | 3kV | 3mA | 9W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS F230p Art.-Nr.: EH162030p305 konfigurieren | 3kV | 3mA | 9W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS F240n Art.-Nr.: EH162040n205 konfigurieren | 4kV | 2mA | 8W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS F240p Art.-Nr.: EH162040p205 konfigurieren | 4kV | 2mA | 8W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS F260n Art.-Nr.: EH162060n105 konfigurieren | 6kV | 1mA | 6W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS F260p Art.-Nr.: EH162060p105 konfigurieren | 6kV | 1mA | 6W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L TC VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 4280x Art.-Nr.: EH042080x105 konfigurieren | 8kV | 1mA | 5W | 4 | custom | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 4280n Art.-Nr.: EH042080n105 konfigurieren | 8kV | 1mA | 5W | 4 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 4280p Art.-Nr.: EH042080p105 konfigurieren | 8kV | 1mA | 5W | 4 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU L VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 42100n Art.-Nr.: EH042100n754 konfigurieren | 10kV | 0.75mA | 5W | 4 | negativ | 5mV | CAN | KINGS | 19" Einschub Kassette | 1CR ID IU L VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 42100p Art.-Nr.: EH042100p754 konfigurieren | 10kV | 0.75mA | 5W | 4 | positiv | 5mV | CAN | KINGS | 19" Einschub Kassette | 1CR ID IU L VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 42100x Art.-Nr.: EH042100x754 konfigurieren | 10kV | 0.75mA | 5W | 4 | custom | 5mV | CAN | KINGS | 19" Einschub Kassette | 1CR ID IU L VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 42200n Art.-Nr.: EH042200n404 konfigurieren | 20kV | 0.4mA | 5W | 4 | negativ | 10mV | CAN | KINGS | 19" Einschub Kassette | 1CR ID IU L VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 42200p Art.-Nr.: EH042200p404 konfigurieren | 20kV | 0.4mA | 5W | 4 | positiv | 10mV | CAN | KINGS | 19" Einschub Kassette | 1CR ID IU L VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 42200x Art.-Nr.: EH042200x404 konfigurieren | 20kV | 0.4mA | 5W | 4 | custom | 10mV | CAN | KINGS | 19" Einschub Kassette | 1CR ID IU L VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 42150x Art.-Nr.: konfigurieren | 15kV | 0.5mA | 5W | 4 | custom | 5mV | CAN | KINGS | 19" Einschub Kassette | 1CR ID IU L VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 42150n Art.-Nr.: EH042150n504 konfigurieren | 15kV | 0.5mA | 5W | 4 | negativ | 5mV | CAN | KINGS | 19" Einschub Kassette | 1CR ID IU L VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in CFG | EHS 42150p Art.-Nr.: EH042150p504 konfigurieren | 15kV | 0.5mA | 5W | 4 | negativ | 5mV | CAN | KINGS | 19" Einschub Kassette | 1CR ID IU L VCT SLA SLP | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 8401n Art.-Nr.: EH084001n106 konfigurieren | 100V | 10mA | 1W | 8 | negativ | 3mV | CAN | BNC | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 8401p Art.-Nr.: EH084001p106 konfigurieren | 100V | 10mA | 1W | 8 | positiv | 3mV | CAN | BNC | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 8405n Art.-Nr.: EH084005n106 konfigurieren | 500V | 10mA | 5W | 8 | negativ | 3mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 8405p Art.-Nr.: EH084005p106 konfigurieren | 500V | 10mA | 5W | 8 | positiv | 3mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 8410n Art.-Nr.: EH084010n805 konfigurieren | 1kV | 8mA | 8W | 8 | negativ | 3mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 8410p Art.-Nr.: EH084010p805 konfigurieren | 1kV | 8mA | 8W | 8 | positiv | 3mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 8420n Art.-Nr.: EH084020n405 konfigurieren | 2kV | 4mA | 8W | 8 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 8420p Art.-Nr.: EH084020p405 konfigurieren | 2kV | 4mA | 8W | 8 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 8430n Art.-Nr.: EH084030n305 konfigurieren | 3kV | 3mA | 9W | 8 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 8430p Art.-Nr.: EH084030p305 konfigurieren | 3kV | 3mA | 9W | 8 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 8440n Art.-Nr.: EH084040n205 konfigurieren | 4kV | 2mA | 8W | 8 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 8440p Art.-Nr.: EH084040p205 konfigurieren | 4kV | 2mA | 8W | 8 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 8460n Art.-Nr.: EH084060n105 konfigurieren | 6kV | 1mA | 6W | 8 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 8460p Art.-Nr.: EH084060p105 konfigurieren | 6kV | 1mA | 6W | 8 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS F401n Art.-Nr.: EH164001n106 konfigurieren | 100V | 10mA | 1W | 16 | negativ | 3mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS F401p Art.-Nr.: EH164001p106 konfigurieren | 100V | 10mA | 1W | 16 | positiv | 3mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS F405n Art.-Nr.: EH164005n106 konfigurieren | 500V | 10mA | 5W | 16 | negativ | 3mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS F405p Art.-Nr.: EH164005p106 konfigurieren | 500V | 10mA | 5W | 16 | positiv | 3mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS F410n Art.-Nr.: EH164010n805 konfigurieren | 1kV | 8mA | 8W | 16 | negativ | 3mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS F420n Art.-Nr.: EH164020n405 konfigurieren | 2kV | 4mA | 8W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS F420p Art.-Nr.: EH164020p405 konfigurieren | 2kV | 4mA | 8W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS F430n Art.-Nr.: EH164030n305 konfigurieren | 3kV | 3mA | 9W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS F430p Art.-Nr.: EH164030p305 konfigurieren | 3kV | 3mA | 9W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS F440n Art.-Nr.: EH164040n205 konfigurieren | 4kV | 2mA | 8W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS F440p Art.-Nr.: EH164040p205 konfigurieren | 4kV | 2mA | 8W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS F460n Art.-Nr.: EH164060n105 konfigurieren | 6kV | 1mA | 6W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS F460p Art.-Nr.: EH164060p105 konfigurieren | 6kV | 1mA | 6W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | 1CR ID IU TC SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 44200p Art.-Nr.: EH044200p404 konfigurieren | 20kV | 0.4mA | 8W | 4 | positiv | 10mV | CAN | KINGS | 19" Einschub Kassette | 1CR ID IU L SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 44200n Art.-Nr.: EH044200n404 konfigurieren | 20kV | 0.4mA | 8W | 4 | negativ | 10mV | CAN | KINGS | 19" Einschub Kassette | 1CR ID IU L SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 44150n Art.-Nr.: EH044150n504 konfigurieren | 15kV | 0.5mA | 8W | 4 | negativ | 5mV | CAN | KINGS | 19" Einschub Kassette | 1CR ID IU L SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 44150p Art.-Nr.: EH044150p504 konfigurieren | 15kV | 0.5mA | 8W | 4 | positiv | 5mV | CAN | KINGS | 19" Einschub Kassette | 1CR ID IU L SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 44100n Art.-Nr.: EH044100n754 konfigurieren | 10kV | 0.75mA | 5W | 4 | negativ | 5mV | CAN | KINGS | 19" Einschub Kassette | 1CR ID IU L SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS High Precision in FG | EHS 44100p Art.-Nr.: EH044100p754 konfigurieren | 10kV | 0.75mA | 5W | 4 | positiv | 5mV | CAN | KINGS | 19" Einschub Kassette | 1CR ID IU L SLA SLP F02 F20 | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 42100n-L Art.-Nr.: EH042100n104 konfigurieren | 10kV | 100µA | 8W | 4 | negativ | 5mV | CAN | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS | |
| EHS Lower Current | EHS 42100p-L Art.-Nr.: EH042100p104 konfigurieren | 10kV | 100µA | 8W | 4 | positiv | 5mV | CAN | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS | |
| EHS Lower Current | EHS 42100x-L Art.-Nr.: EH042100x104 konfigurieren | 10kV | 100µA | 8W | 4 | custom | 5mV | CAN | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS | |
| EHS Lower Current | EHS 42200n-L Art.-Nr.: EH042200n104 konfigurieren | 20kV | 100µA | 8W | 4 | negativ | 5mV | CAN | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS | |
| EHS Lower Current | EHS 42200p-L Art.-Nr.: EH042200p104 konfigurieren | 20kV | 100µA | 8W | 4 | positiv | 5mV | CAN | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS | |
| EHS Lower Current | EHS 42200x-L Art.-Nr.: EH042200x104 konfigurieren | 20kV | 100µA | 8W | 4 | custom | 5mV | CAN | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS | |
| EHS Lower Current | EHS 4280x-L Art.-Nr.: EH042080x104 konfigurieren | 8kV | 100µA | 8W | 4 | custom | 5mV | CAN | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS | |
| EHS Lower Current | EHS 4280n-L Art.-Nr.: EH042080n104 konfigurieren | 8kV | 100µA | 8W | 4 | negativ | 5mV | CAN | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS | |
| EHS Lower Current | EHS 4280p-L Art.-Nr.: EH042080p104 konfigurieren | 8kV | 100µA | 8W | 4 | positiv | 5mV | CAN | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS | |
| EHS Lower Current | EHS 8205x-L Art.-Nr.: EH082005x104 konfigurieren | 500V | 100µA | 8W | 8 | custom | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8205p-L Art.-Nr.: EH082005p104 konfigurieren | 500V | 100µA | 8W | 8 | positiv | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8205n-L Art.-Nr.: EH082005n104 konfigurieren | 500V | 100µA | 8W | 8 | negativ | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8230x-L Art.-Nr.: EH082030x104 konfigurieren | 3kV | 100µA | 8W | 8 | custom | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8230p-L Art.-Nr.: EH082030p104 konfigurieren | 3kV | 100µA | 8W | 8 | positiv | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8230n-L Art.-Nr.: EH082030n104 konfigurieren | 3kV | 100µA | 8W | 8 | negativ | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8201x-L Art.-Nr.: EH082001x104 konfigurieren | 100V | 0.1mA | 0.01W | 8 | custom | 3mV | CAN | BNC | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8201n-L Art.-Nr.: EH082001n104 konfigurieren | 100V | 0.1mA | 0.01W | 8 | negativ | 3mV | CAN | BNC | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8201p-L Art.-Nr.: EH082001p104 konfigurieren | 100V | 0.1mA | 0.01W | 8 | positiv | 3mV | CAN | BNC | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8210n-L Art.-Nr.: EH082010n104 konfigurieren | 1kV | 100µA | 0.1W | 8 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8210p-L Art.-Nr.: EH082010p104 konfigurieren | 1kV | 100µA | 0.1W | 8 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8220n-L Art.-Nr.: EH082020n104 konfigurieren | 2kV | 100µA | 0.2W | 8 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8220p-L Art.-Nr.: EH082020p104 konfigurieren | 2kV | 100µA | 0.2W | 8 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8240n-L Art.-Nr.: EH082040n104 konfigurieren | 4kV | 100µA | 0.4W | 8 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8240p-L Art.-Nr.: EH082040p104 konfigurieren | 4kV | 100µA | 0.4W | 8 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8260n-L Art.-Nr.: EH082060n104 konfigurieren | 6kV | 100µA | 0.6W | 8 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8260p-L Art.-Nr.: EH082060p104 konfigurieren | 6kV | 100µA | 0.6W | 8 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F205x-L Art.-Nr.: EH162005x104 konfigurieren | 500V | 100µA | 8W | 16 | custom | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F205n-L Art.-Nr.: EH162005n104 konfigurieren | 500V | 100µA | 8W | 16 | negativ | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F205p-L Art.-Nr.: EH162005p104 konfigurieren | 500V | 100µA | 8W | 16 | positiv | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F230n-L Art.-Nr.: EH162030n104 konfigurieren | 3kV | 100µA | 8W | 16 | negativ | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F230p-L Art.-Nr.: EH162030p104 konfigurieren | 3kV | 100µA | 8W | 16 | positiv | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F230x-L Art.-Nr.: EH162030x104 konfigurieren | 3kV | 100µA | 8W | 16 | custom | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F201x-L Art.-Nr.: EH162001x104 konfigurieren | 100V | 100µA | 0.01W | 16 | custom | 3mV | CAN | BNC | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F201n-L Art.-Nr.: EH162001n104 konfigurieren | 100V | 100µA | 0.01W | 16 | negativ | 3mV | CAN | BNC | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F201p-L Art.-Nr.: EH162001p104 konfigurieren | 100V | 100µA | 0.01W | 16 | positiv | 3mV | CAN | BNC | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F210n-L Art.-Nr.: EH162010n104 konfigurieren | 1kV | 100µA | 0.1W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F210p-L Art.-Nr.: EH162010p104 konfigurieren | 1kV | 100µA | 0.1W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F220n-L Art.-Nr.: EH162020n104 konfigurieren | 2kV | 100µA | 0.2W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F220p-L Art.-Nr.: EH162020p104 konfigurieren | 2kV | 100µA | 0.2W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F240n-L Art.-Nr.: EH162040n104 konfigurieren | 4kV | 100µA | 0.4W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F240p-L Art.-Nr.: EH162040p104 konfigurieren | 4kV | 100µA | 0.4W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F260n-L Art.-Nr.: EH162060n104 konfigurieren | 6kV | 100µA | 0.6W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F260p-L Art.-Nr.: EH162060p104 konfigurieren | 6kV | 100µA | 0.6W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 44200n-L Art.-Nr.: EH044200n104 konfigurieren | 20kV | 100µA | 8W | 4 | negativ | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 44200p-L Art.-Nr.: EH044200p104 konfigurieren | 20kV | 100µA | 8W | 4 | positiv | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 44200x-L Art.-Nr.: EH440200x104 konfigurieren | 20kV | 100µA | 8W | 4 | custom | 10mV | CAN | KINGS | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 44100n-L Art.-Nr.: EH044100n104 konfigurieren | 10kV | 100µA | 5W | 4 | negativ | 5mV | CAN | KINGS | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 44100x-L Art.-Nr.: EH044100x104 konfigurieren | 10kV | 100µA | 5W | 4 | custom | 5mV | CAN | KINGS | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 44100p-L Art.-Nr.: EH044100p104 konfigurieren | 10kV | 100µA | 5W | 4 | positiv | 5mV | CAN | KINGS | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8405n-L Art.-Nr.: EH084005n104 konfigurieren | 500V | 100µA | 8W | 8 | negativ | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8405p-L Art.-Nr.: EH084005p104 konfigurieren | 500V | 100µA | 8W | 8 | positiv | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8405x-L Art.-Nr.: EH084005x104 konfigurieren | 500V | 100µA | 8W | 8 | custom | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8430n-L Art.-Nr.: EH084030n104 konfigurieren | 3kV | 100µA | 8W | 8 | negativ | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8430p-L Art.-Nr.: EH084030p104 konfigurieren | 3kV | 100µA | 8W | 8 | positiv | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8430x-L Art.-Nr.: EH084030x104 konfigurieren | 3kV | 100µA | 8W | 8 | custom | 5mV | CAN | REDEL | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8401x-L Art.-Nr.: EH084001x104 konfigurieren | 100V | 100µA | 0.01W | 8 | custom | 3mV | CAN | BNC | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8401n-L Art.-Nr.: EH084001n104 konfigurieren | 100V | 100µA | 0.01W | 8 | negativ | 3mV | CAN | BNC | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8401p-L Art.-Nr.: EH084001p104 konfigurieren | 100V | 100µA | 0.01W | 8 | positiv | 3mV | CAN | BNC | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8410n-L Art.-Nr.: EH084010n104 konfigurieren | 1kV | 100µA | 0.1W | 8 | negativ | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8410p-L Art.-Nr.: EH084010p104 konfigurieren | 1kV | 100µA | 0.1W | 8 | positiv | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8420n-L Art.-Nr.: EH084020n104 konfigurieren | 2kV | 100µA | 0.2W | 8 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8420p-L Art.-Nr.: EH084020p104 konfigurieren | 2kV | 100µA | 0.2W | 8 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8440n-L Art.-Nr.: EH084040n104 konfigurieren | 4kV | 100µA | 0.4W | 8 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8440p-L Art.-Nr.: EH084040p104 konfigurieren | 4kV | 100µA | 0.4W | 8 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8460n-L Art.-Nr.: EH084060n104 konfigurieren | 6kV | 100µA | 0.6W | 8 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS 8460p-L Art.-Nr.: EH084060p104 konfigurieren | 6kV | 100µA | 0.6W | 8 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F401x-L Art.-Nr.: EH164001x104 konfigurieren | 100V | 100µA | 0.01W | 16 | custom | 3mV | CAN | BNC | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F401n-L Art.-Nr.: EH164001n104 konfigurieren | 100V | 100µA | 0.01W | 16 | negativ | 3mV | CAN | BNC | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F401p-L Art.-Nr.: EH164001p104 konfigurieren | 100V | 100µA | 0.01W | 16 | positiv | 3mV | CAN | BNC | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F410n-L Art.-Nr.: EH164010n104 konfigurieren | 1kV | 100µA | 0.1W | 16 | negativ | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F410p-L Art.-Nr.: EH164010p104 konfigurieren | 1kV | 100µA | 0.1W | 16 | positiv | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F405n-L Art.-Nr.: EH164005n104 konfigurieren | 500V | 100µA | 5W | 16 | negativ | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F405p-L Art.-Nr.: EH164005p104 konfigurieren | 500V | 100µA | 5W | 16 | positiv | 3mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F420n-L Art.-Nr.: EH164020n104 konfigurieren | 2kV | 100µA | 0.2W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F420p-L Art.-Nr.: EH164020p104 konfigurieren | 2kV | 100µA | 0.2W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F440n-L Art.-Nr.: EH164040n104 konfigurieren | 4kV | 100µA | 0.4W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F440p-L Art.-Nr.: EH164040p104 konfigurieren | 4kV | 100µA | 0.4W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F430n-L Art.-Nr.: EH164030n104 konfigurieren | 3kV | 100µA | 9W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F430p-L Art.-Nr.: EH164030p104 konfigurieren | 3kV | 100µA | 9W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F460n-L Art.-Nr.: EH164060n104 konfigurieren | 6kV | 100µA | 0.6W | 16 | negativ | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F460p-L Art.-Nr.: EH164060p104 konfigurieren | 6kV | 100µA | 0.6W | 16 | positiv | 5mV | CAN | SHV | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F610n-L Art.-Nr.: EH166010n104 konfigurieren | 1kV | 100µA | 5W | 4 | negativ | 5mV | CAN | KINGS | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| EHS Lower Current | EHS F610p-L Art.-Nr.: EH166010p104 konfigurieren | 1kV | 100µA | 5W | 4 | positiv | 5mV | CAN | KINGS | 19" Einschub Kassette | ID IU L TC | ![]() | Handbuch EHS |
| Code | Beschreibung |
|---|---|
| 1CR | ein Strommessbereich für Hochpräzisionsmodule |
| ID | single-channel INHIBIT - down |
| IU | single-channel INHIBIT - up |
| L | Version mit niedrigem Ausgangsstrom |
| VCT | temperaturabhängige Spannungskorrektur |
| SLA | aktive Sicherheitsschleife |
| SLP | intern gespeiste Sicherheitsschleife |
| F02 | 200V Isolationsfestigkeit für Floating Ground |
| F20 | 2000V Isolationsfestigkeit für Floating Ground |
| TC | verbesserter Temperaturkoeffizient |
| NID | negierte Logik für inhibit down pro Kanal |
| NIU | negierte Logik für inhibit up pro Kanal |
Konfigurator
Dieses Tool hilft dabei, ein iseg-Gerätekonfiguration auszuwählen und mit passenden Optionen und Schnittstellen zu einer bestellbaren Artikelvariante und finaler Artikelnummer zu kombinieren. Ebenso kann es verwendet werden, um bekannte Artikelnummern zu dekodieren.
Hinweis: Handbücher und Datenblätter können im Konfigurationen-Tab heruntergeladen werden.