Home > SYSTEMS > NHS

go back
SYSTEM-NIM

NHS

High Precision Versatile High Voltage Module in NIM Standard

The iseg NHS modules of this series are multi channel high voltage power supplies in 1/12 NIM standard cassette format. With up to 6 channels each single channel has an independent voltage and current control. By offering different configurations and options this module perfectly covers various types of applications such as detector supply, experimental setup or lab use.

Several NHS modules can be daisychained by CAN and controlled with a single USB connection or by iseg iCS system. The module is made of best components as 24 bit ADC and 20 bit DAC, an excellent front panel control with TFT display plus comprehensive security features.


  • very low ripple and noise
  • front panel control with 1,44“ TFT display
  • hardware voltage and current limits
  • voltage and current control per channel
  • USB, CAN interfaces
  • programmable parameters

model NHS High Precision Lower ... NHS standard NHS High Precision
ch. 6 6 6
Vnom 100V - 6kV 100V - 6kV 100V - 6kV
Vin +24V, -24V, +6V +24V, -24V, +6V +24V, -24V, +6V
ripple & noise 1mV - 20mV 5mV - 30mV 3mV - 20mV
HV connector BNC, SHV SHV, BNC SHV, BNC
control iCS, SCPI Control iCS, SCPI Control iCS, SCPI Control
options ID IU TC ID IU TC ID IU TC
manual Manual Manual Manual
datasheet see configurations see configurations see configurations
image NHS NHS NHS
current new planned discontinued
group
model
Vnom
Inom
Pnom/ch
ch.
polarity
ripple & noise
interfaces
HV connector
case
options
image
manual
NHS High Precision Lower ...NHS 6201x-L
itemcode: NH062001x104
configure now
100V100µA0.01W6custom1mVUSB CANBNC1/12 NIM standard cassett...ID IU TCNHSManual
NHS High Precision Lower ...NHS 6201n-L
itemcode: NH062001n104
configure now
100V100µA0.01W6negativ1mVUSB CANBNC1/12 NIM standard cassett...ID IU TCNHSManual
NHS High Precision Lower ...NHS 6201p-L
itemcode: NH062001p104
configure now
100V100µA0.01W6positiv1mVUSB CANBNC1/12 NIM standard cassett...ID IU TCNHSManual
NHS High Precision Lower ...NHS 6210x-L
itemcode: NH062010x104
configure now
1kV100µA0.1W6custom5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High Precision Lower ...NHS 6210n-L
itemcode: NH062010n104
configure now
1kV100µA0.1W6negativ5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High Precision Lower ...NHS 6210p-L
itemcode: NH062010p104
configure now
1kV100µA0.1W6positiv5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High Precision Lower ...NHS 6220x-L
itemcode: NH062020x104
configure now
2kV100µA0.2W6custom5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High Precision Lower ...NHS 6220n-L
itemcode: NH062020n104
configure now
2kV100µA0.2W6negativ5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High Precision Lower ...NHS 6220p-L
itemcode: NH062020p104
configure now
2kV100µA0.2W6positiv5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High Precision Lower ...NHS 6240x-L
itemcode: NH062040x104
configure now
4kV100µA0.4W6custom5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High Precision Lower ...NHS 6240n-L
itemcode: NH062040n104
configure now
4kV100µA0.4W6negativ5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High Precision Lower ...NHS 6240p-L
itemcode: NH062040p104
configure now
4kV100µA0.4W6positiv5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High Precision Lower ...NHS 6260x-L
itemcode: NH062060x104
configure now
6kV100µA0.6W6custom20mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High Precision Lower ...NHS 6260n-L
itemcode: NH062060n104
configure now
6kV100µA0.6W6negativ20mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High Precision Lower ...NHS 6260p-L
itemcode: NH062060p104
configure now
6kV100µA0.6W6positiv20mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High Precision Lower ...NHS 6205n-L
itemcode: NH062005n104
configure now
500V100µA0.05W6negativ5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High Precision Lower ...NHS 6205p-L
itemcode: NH062005p104
configure now
500V100µA0.05W6positiv5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High Precision Lower ...NHS 6205x-L
itemcode: NH062005x104
configure now
500V100µA0.05W6custom5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6005n
itemcode: NH060005n156
configure now
500V15mA6negativ5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6005p
itemcode: NH060005p156
configure now
500V15mA6positiv5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6005x
itemcode: NH060005x156
configure now
500V15mA6custom5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6001x
itemcode: NH060001x106
configure now
100V10mA1W6custom5mVUSB CANBNC1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6001n
itemcode: NH060001n106
configure now
100V10mA1W6negativ5mVUSB CANBNC1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6001p
itemcode: NH060001p106
configure now
100V10mA1W6positiv5mVUSB CANBNC1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6010x
itemcode: NH060010x805
configure now
1kV8mA6W6custom10mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6010n
itemcode: NH060010n805
configure now
1kV8mA6W6negativ10mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6010p
itemcode: NH060010p805
configure now
1kV8mA6W6positiv10mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6020x
itemcode: NH060020x405
configure now
2kV4mA8W6custom10mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6020n
itemcode: NH060020n405
configure now
2kV4mA8W6negativ10mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6020p
itemcode: NH060020p405
configure now
2kV4mA8W6positiv10mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6030x
itemcode: NH060030x305
configure now
3kV3mA9W6custom10mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6030n
itemcode: NH060030n305
configure now
3kV3mA9W6negativ10mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6030p
itemcode: NH060030p305
configure now
3kV3mA9W6positiv10mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6040x
itemcode: NH060040x205
configure now
4kV2mA8W6custom10mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6040n
itemcode: NH060040n205
configure now
4kV2mA8W6negativ10mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6040p
itemcode: NH060040p205
configure now
4kV2mA8W6positiv10mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6060x
itemcode: NH060060x105
configure now
6kV1mA6W6custom30mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6060n
itemcode: NH060060n105
configure now
6kV1mA6W6negativ30mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS standardNHS 6060p
itemcode: NH060060p105
configure now
6kV1mA6W6positiv30mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6205n
itemcode: NH062005n106
configure now
500V10mA6negativ5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6205p
itemcode: NH062005p106
configure now
500V10mA6positiv5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6205x
itemcode: NH062005x106
configure now
500V10mA6custom5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6201x
itemcode: NH062001x106
configure now
100V10mA1W6custom3mVUSB CANBNC1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6201n
itemcode: NH062001n106
configure now
100V10mA1W6negativ3mVUSB CANBNC1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6201p
itemcode: NH062001p106
configure now
100V10mA1W6positiv3mVUSB CANBNC1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6210x
itemcode: NH062010x805
configure now
1kV8mA6W6custom5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6210n
itemcode: NH062010n805
configure now
1kV8mA6W6negativ5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6210p
itemcode: NH062010p805
configure now
1kV8mA6W6positiv5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6220x
itemcode: NH062020x405
configure now
2kV4mA8W6custom5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6220n
itemcode: NH062020n405
configure now
2kV4mA8W6negativ5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6220p
itemcode: NH062020p405
configure now
2kV4mA8W6positiv5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6230x
itemcode: NH062030x305
configure now
3kV3mA9W6custom5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6230n
itemcode: NH062030n305
configure now
3kV3mA9W6negativ5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6230p
itemcode: NH062030p305
configure now
3kV3mA9W6positiv5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6240x
itemcode: NH062040x205
configure now
4kV2mA8W6custom5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6240n
itemcode: NH062040n205
configure now
4kV2mA8W6negativ5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6240p
itemcode: NH062040p205
configure now
4kV2mA8W6positiv5mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6260x
itemcode: NH062060x105
configure now
6kV1mA6W6custom20mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6260n
itemcode: NH062060n105
configure now
6kV1mA6W6negativ20mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
NHS High PrecisionNHS 6260p
itemcode: NH062060p105
configure now
6kV1mA6W6positiv20mVUSB CANSHV1/12 NIM standard cassett...ID IU TCNHSManual
code description
ID single-channel INHIBIT - down
IU single-channel INHIBIT - up
TC improved temperature coefficient

configuration tool

This tool helps to select a suitable iseg device and to combine suitable options and interfaces into an product that can be ordered with a final article number. It can also be used to decode known item codes.
 
search
 
reset

Product preview

Note: manuals and datasheets can be downloaded under configurations-tab